Speed Queen none Clothes Dryer User Manual


 
Installation
23
70256801
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 6
How to Change Injector (Orifice) Size
1. Disconnect electrical power from tumbler. Close
gas shut-off valve to tumbler. Refer to
Figure 5.
2. Remove gas valve.
Johnson G96 Gas Valve – Unscrew spud holder
nut near gas valve. Refer to
Figure 7. Remove the
burner orifice(s) from spud holder. Refer to
Figure 6.
3. Install the new, correct injector(s) (orifices).
Refer to
Figure 8. Torque each to 9-10 Nm.
4. Reinstall spud holder assembly to gas valve,
making certain orifice(s) are in line with burner
tube opening. Refer to
Figure 6.
5. Commission tumbler for use.
NOTE: Blank injectors (orifices) are Part No.
M400995.
TMB1527N
1 Burner 7 Nut
2 Gas Valve 8 Anti-Torque Ring
3 Regulator Plate 9 Manifold Pipe
4 Gasket 10 Spud Holder
5 Plate 11 Burner Orifice
6 Regulator Cap
TMB1527N
UNREGULATED (REGULATOR BLOCKED OPEN)
1
10
9
8
7
6
5
4
3
2
11