ALIGNMENT AND ADJUSTMENTS
6
EEPROM Clear Check
Denition of EEPROM Clear Mode:
- EEPROM initialization.
- All course/option settings are to be reset to default values
after EEPROM initialization.
- When Service arises and it needs PCB replacement,
EEPROM should be reset.
How to Enter:
- The machine must be turned o.
-
Press Delay Start Key, Power Key at the same time.
Continuous Run Mode
Denition of Continuous Run Mode:
- Will continuously repeat the current cycle until the Continuous Run Mode is cancelled.
How to Enter:
- Press DelayStart + ExtraRinse together for 7 sec.
Continuous Run Mode:
1. Press
DelayStart + ExtraRinse 7 sec
during Power On State (Normal User Mode) .
2.
Once in Continuous Run Mode, The seven segments will no longer display “0000” and will alternate
between displaying the number of cycles of the completed course and the remaining time of the course.
3. The Continuous Run Mode will repeat the previous cycle until continuous run mode is cancelled.
4.
During Continuous Run Mode, press DelayStart + ExtraRinse 7 seconds to return to normal user
mode. The seven segments will no longer display the number of cycles and will display the
maintenance time only.
5. If power is lost in Continuous Run Mode (that is, when the power plug is disconnected or the
Power key is pressed turning the washing machine o), the mode is released when the washing
machine is turned on again.
To avoid risk of electrical shock, personal injury or death; disconnect power to washer
before servicing, unless testing requires power.
WARNING
WF395BTP-03144B-01_EN.indd 6 2012-10-19 �� 2:05:55