Description Corrective Action
11 tE tE
Abnormal high/low temperature or
resistance (Thermal sensor or PBA
resistance).
Go to “ Board Input Test” and check
Water Temperature. Check loose
or pinched wires. Replace PCB or
thermistor.
12
3E 3E
MICOM is attempting to drive the motor
but is not getting any response signals
from the hall sensor. Visual check shows
motor is not running. (Locked, Defective
Hall Sensor or Overload)
Evaluate wire harness for loose or
unhooked connections. Go to “
Quick Test Mode” and test Motor.
13
Hr Hr
This error code appears when the
heater is 96°C or above.
Replace PCB
14
nF1 nF1
This error code appears when the
water temperature is 50°C or above
for 8 seconds or longer in the Wool
and Delicate course.
Please connect the hot/cold water
hose connection correctly.
15 suds suds
Suds is detected during the washing
session. (“SUdS” is not an error. If the
washer is in suds period, “SUdS” will
light up instead of remaining time.)
Guide a user to reduce amount of
detergent usage.
16 AE AE
Communication error between SUB
PBA and MAIN PBA
Check Main PBA, SUB PBA & Wire-
harness. Replace PCB
17 SF SF
System Error Replace PCB
18 2E 2E
Voltage for motor control bus is
over or under specied limit.
Replace PCB