Samsung WF393BTPAWR Washer User Manual


 
ALIGNMENT AND ADJUSTMENTS
2
GENERAL ERROR FUNCTION
NO
Error
Code
Diagnostic Code
Error Image
Description Corrective Action
1 nd nd
The water level fails to drop below
the Reset Water Level within 15
minutes.
Go to “ Will Not Drain”
Troubleshooting Section.
2 LO LO
Door fails to Unlock After 7
attempts.
Go to “ Will Not Unlock”
Troubleshooting Section.
3 nF nF
When the lling Continues for
more than 40 minutes or there is no
change of water level for 6 minutes.
Go to “ No Water Fill”
Troubleshooting Section.
4 FL FL
Door fails to lock after 7 attempts.
Go to “ Will Not Lock”
Troubleshooting Section.
5 LE LE
A water level lower than the Reset
water level (25.6Khz) is detected for
5 seconds during the Wash/Rinse
cycle.
Go to “No Water Fill”
Troubleshooting Section.
6 LE(1E) LE(1E)
Water Level Sensor Trouble. (When
the input signal from the water level
sensor is out of range, the unit will
send out beeping sounds and halts
the cycle.)
Go to “No Water Fill”
Troubleshooting Section
7 OE OE
A fault is detected in the water level
sensor. Data (frequency) shows
the water level is at or above the
overow water level. (When this
condition is detected, the machine
will automatically starts draining
water until the water level falls
below the overow water level)
First check to see that all of water
valves are not stuck. If water valves
are OK, check water level sensor.
8 dc dc
Unbalance or cabinet bump is
detected during nal spin, which
prevents the drum from spinning
over 140 rpm. (Never exceeds 150
RPM due to unbalanced load)
Go to “Wet Clothes”
Troubleshooting Section.
9 E2 E2
Jammed Key.(When key input
signals are coming out for more
than 30 seconds, it is regarded as
a jam.)
Check all of keys. If A key is sensed
to be pressed, all keys will do not
respond.
10 ds ds
Door is detected as open while it is
trying to lock the door.
Go to “Quick Test Mode” and then
do Door Lock/Unlock Test
To avoid risk of electrical shock, personal injury or death; disconnect power to washer
before servicing, unless testing requires power.
WARNING
WF395BTP-03144B-01_EN.indd 2 2012-10-19 �� 2:05:54