18.Open the gas shut off valve inside the upper dryer (see figures 42 & 43), and check the union
connectionto the gas valve for leaks using a soap solution, DO NOT use an open flame to check for
gas leaks. If bubbles occur,tighten the connectionsand recheck. Make sure not to let solution drip
into any electrical connector or component.
NOTE: As a courtesy, many local gas utilities will inspect a gas appliance installation. Check with your
local utilityto see if this service is provided in your area.
NOTE: The minimumpermissible gas (naturalor mixed)supply pressure for purposes of input
adjustment is 4.5 inchesof water.
Figure42 Figure43
19.Removewire harnessesand plastic clips from base (see figure 44) and connect each harnessto the
connector in the washer making sure locking tabs are engaged, and harness is tucked out of the way of
the dispenser. (See figures 45 & 46.)
Figure 45
7 ii_iii
Figure 44
L
Figure 46