Equator MD3720CEE Washer/Dryer User Manual


 
8
is present, the machine should fill. If not, the valve is defective.
2) Unit fills, won’t agitate / tumble
a) Belt: Check belt, adjust tension.
b) Motor Bolts: Check if the motor is bolted properly.
c) Pressure Switch: Set the washer knob to Towels / Sheets position. Switch on the unit. The
unit should fill in water and stop to fill. After the unit stops filling, test for 115V AC across
Pin#14 of the pressure switch and terminal#2 on the control module. If present the pressure
switch is fine, if not present the pressure switch is defective.
d) Motor: Remove the motor connector. Set the washer knob to Towels / Sheets position.
Switch on the unit. The unit should fill in water and stop to fill. After the unit stops filling,
check AC voltage between wires M3 & M5 on the motor connector, it should toggle between
115V AC & 16V AC, similar should be observed between M7 & M5, if found as above the
motor is bad or else the wash timer is bad.
e) Wash Timer: Remove the motor connector. Set the washer knob to Towels / Sheets
position. Switch on the unit. The unit Should fill in water and stop to fill. After the unit stops
filling, check AC voltage between wires M3 & M5 on the motor connector, it should toggle
between 115V AC & 15V AC, similar should be observed between M7 & M5, if found as
above the motor is bad or else the timer is bad.
3) Unit won’t drain out water
a) Filter / Coin Trap: Unplug the unit. Remove foreign objects if any from the filter housing and
clean the filter.
b) Drain hose: Check for kinks or blockage.
c) Drain outlet above 36”: Drain standpipe inlet more than 36" above the floor.
d) Pump: Set Wash timer knob to Spin (One click away from off) and switch on the power.
Test for 115V AC at the pump connector, if present the pump is bad, if 115V AC is not
present the timer is bad.
e) Wash Timer: Set Wash timer knob to Spin (One click away from off) and switch on the
power. Test for 115V AC at the pump connector, if present the pump is bad, if 115V AC is
not present the timer is bad.
4) Unit is noisy
a) Unit not leveled: Adjust leveling legs, tighten lock nuts.
b) Foreign object in tub: Check tub, remove object.
c) Shock Absorbers: Check that attachment bolts are tight. Press the inner drum downwards
and experience the force to do so, if enough force is required the shocks are good or else
they are bad.
5) Unit Vibrates
a) Shipping bolts not removed: There are 3 shipping bolts which must be removed along
with the 3 spacers.