American Dryer Corp. None Clothes Dryer User Manual


 
45
MED KEY- SETTING DRY TEMP 100 TO 190 °F *
PROGRAM MODE
PL #01
CONTROL
SETTINGS
PL #04 MED KEY
SETTINGS
TIME FOR AMOUNT TO
START 1 TO 99
MINUTES
READY, INSERT
0.25 ¢ TO START
PRESS "MED" TO
ENTER PL #04 MED KEY
SETTINGS.
PRESS "HI"
THREE (3)
TIMES TO
SCAN UP
TO PL #04 MED
KEY SETTINGS.
PRESS "MED" TO
ENTER DRY TEMP
PARAMETER.
PRESS "HI" OR
"LO" TO
INCREASE OR
DECREASE DRY
TEMP.
PRESS "MED" TO
SELECT DRY TEMP
AND ADVANCE TO
NEXT
PARAMETER.
PRESS "MED"
TO ENTER
PROGRAM
MENU.
FROM READY MODE
TOGGLE PROGRAM
SWITCH TO UP
POSITION.
NOTE: PRESS "PAUSE" TO
EXIT PL #04 MED KEY
SETTINGS MEMORY
LOCATION
180
190
COOL TIME 0 TO
9 MINUTES
DRY TEMP 100 TO 190
°F
PRESS "HI" TO SCAN
UP TO DRY TEMP
SETTING.
* NOTE- THE MAX TEMP WILL BE
REGULATED BASED ON THE RADIAL
OR AXIAL CONFIGURATION OF DRY.
THE MAX DRYING TEMP FOR A RADIAL
DRYER IS 190 °F AND THE MAX DRYING
TEMP FOR AN AXIAL DRYER IS 150 °F