SELECT VENDING SAFEGUARD
The Phase 7 dual microprocessor controller (DMC) computer can be set to one (1) of the following safeguards:
Bad Coin Reset
When this option is selected and someone tampers with the coin acceptor or inserts a foreign object, the
Phase 7 DMC (computer) will beep three (3) times and will not accept the entry. The Phase 7 DMC (computer)
will automatically reset itself for the next entry.
Bad Coin Lock Out
When this option is selected and someone tampers with the coin acceptor or inserts a foreign object, the
Phase 7 DMC (computer) will Lock Out and will not accept any coins for a period of 15-seconds. After
15-seconds, the Phase 7 DMC (computer) will reset itself for the next entry.
ENTER LEFT/RIGHT COIN DENOMINATION 0.05 TO 25.00
The left and right coin acceptors can be independently set to a value within the range of 0.05 to 25.00, adjustable
in 0.01 increments.
AMOUNT TO START
This location determines the amount needed to start a dry cycle. The AMOUNT TO START is programmable
from a minimum of 0.05 to a maximum of 25.00, adjustable in 0.01 increments.
AMOUNT FOR TOP OFF
This location determines the amount needed to add more time to a dry cycle. The amount for additional time is
programmable from a minimum of 0.05 to a maximum of 25.00 minutes, adjustable in 0.01 increments.
PL #07 – FAULT RECORDING
NO FAULTS
No faults have occurred in the dryer and, therefore, no fault records have been created.
FAULTS
Whenever a fault occurs, the Phase 7 DMC (computer) will store the fault description in this location. The Phase
7 DMC (computer) will also store the hour logger time, and the temperature cycle that the pocket was in at the
time of the fault. The Phase 7 DMC (computer) will store the last five (5) faults that occurred. Every time a new
fault occurs, the oldest fault will be erased and the new fault will be stored.