American Dryer Corp. ADS-464 II Clothes Dryer User Manual


 
63
Tumbler (basket) target...this target is attached to the outside of the basket
Stop motion detector module in the tumbler (basket) section on the left front side
Circuit Wiring; refer to ADS-464 Main Panel Wiring Diagram
ADS-464 Tumbler (Basket) Junction Box Wiring Diagram
C. BASE SECTION ELECTRICAL MALFUNCTIONS
INTRODUCTION
There are four (4) electrical components associated with the ADS-464 base section. These components are
interfaced to a junction box, and connect to the main electrical enclosure through a disconnect cable. The Base
Junction Box is located on the right rear of the base section, and title of its wiring diagram is ADS-464 Base
Electrical Junction Box Wiring Diagram. The base section of electrical components provide:
Tumbler (basket) position information (Front Up - Level - Rear Up)
Lint chamber pressure information
Lint screen mechanism functioning okay information
The following information will provide a means to respond to Base associated Fault Messages, and to verify
ALL the electrical signals associated with the Base Section. Refer to the ADS-464 Base Junction Box for a
detailed wiring diagram.
1.0 Base Section Electrical Components
a. Front Door Switch
The Front Down Sensing Switch is located on the left side of the ADS-464 base and comprises of four
(4) parts; head, arm, body, and cord grip device. The head is a rotating type, with a roller arm attached
for switch actuation. The body contains a double-pole-double-throw (DPDT), normally open switch. LS
has two (2) electrical functions, A and B.
A provides a rear down signal to the PLC (Programmable Logic Controller)
B is used as an electrical interlock to the Rear Up Signal
b. Rear Down Switch - LS2
The Rear Down Sensing Switch is located on the left side of the ADS-464 base, and comprises of four
(4) parts; head, arm, body, and cord grip device. The head is a rotating type, with a roller arm attached
for switch actuation. The body contains a double-pole-double-throw (DPDT), normally open switch.
A provides a rear down signal to the PLC (Programmable Logic Controller)
B is used as an electrical interlock to the Front Up Signal