A. POWER MALFUNCTIONS
1. Main Disconnect Will Not Turn On
a. PROBABLE CAUSES;
1) Sprinkler isolated power source OFF or disabled.
2) OL12 tripped or sprinkler circuit defective.
3) Sprinkler activated.
4) Sprinkler will not reset.
b. POSSIBLE SOLUTIONS;
1) Verify red Sprinkler Power on main panel to be illuminated.
If ON go to paragraph #3 below
If NOT ON verify isolated sprinkler power source to the dryer
Check sprinkler supply voltage at TB1 Pin #4 and Pin #5
If OK go to paragraph #2 below
If none, check incoming line voltage
If none, check fuse disconnect switch
2) Check if OL12 has tripped.
If OK go to paragraph #3 below
If tripped, check sprinkler circuit, then reset and test.
3) Check if sprinkler is activated...is the SPRINKLER RESET button lit?
If YES, press SPRINKLER RESET
Does the sprinkler reset?
If YES, attempt to turn ON the main disconnect again
If NO go to paragraph #4 below and on page 45
4) Sprinkler will not reset, verify that the sprinkler hi-limit has not tripped. (GREEN light is off.)
If it has not tripped, check setting to be 550º F (273º C) and verify that the sprinkler RTD
(Resistive Temperature Device) is connected and has 100 ohms (100 W) at 32º F (0º C)/109
ohms (109 W) at 75º F (24º C)