American Dryer Corp. ADG / MLG-170DR Clothes Dryer User Manual


 
30 American Dryer Corp. 113409-2
M. SHUTDOWN INSTRUCTIONS
If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the heat supply:
a. GAS MODELS ... discontinue the gas supply.
1) SHUT OFF external gas supply shutoff valve.
L. COMPRESSED AIR REQUIREMENTS
The dryer requires an external supply of compressed air (4.25 cfh @ 80 psi [0.12 cmh @ 5.51 bar]). Compressed air is
necessary/required for blower air jet operation to clean lint from the impellor/fan (squirrel cage).
1.
Air Requirements
Shaded areas are stated in metric equivalents
2. Air Regulation
No air regulation or air filtration is provided with the dryer. External regulation/filtration of 80 psi (5.51 bar) must
be provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just
before the dryer connection. This is necessary to ensure that correct and clean air pressure is achieved.
3. Air Connection
Air connection to this system is a 1/4” quick connection as show in the illustration below.
Compressed
Air Supply
Air Pressure
Normal 80 psi
5.51 bar
Minimum Supply 70 psi
4.82 bar
Maximum Supply 90 psi
6.21 bar