Programming
F232101
38
9. If no other supply is required, the next step is to
choose the type of wash desired and assign it a
time. For example, one might choose a wash with
standard reversing action (Wash 1) and a time of
six minutes.
a. Press the Wash key and then key 1. The
display will read W10339.
b. Press the Enter key. The display will read
M---S.
c. Press key 6. The display will read
6M-00S, indicating a wash step of six
minutes.
10. Press the Enter key. The display will read0439,
indicating that the computer is ready for step 4.
11. A drain step usually comes next.
a. Press the Drain key. The display will read
D-0439. This program allows a choice
among drains 1, a, or b. For this application,
press key 1. The display will read D10439.
b. Then press the Enter key. The display will
read M---S.
c. Enter the maximum time desired for the
computer to allow the machine to drain to
empty. The recommended time is one minute.
Press key 1, and the display will change to
1M-00S, indicating a drain step of one
minute.
NOTE: The manufacturer does not recommend
more than one minute for a drain step. If the
machine does not drain in the amount of time
programmed, the EMTY alarm will be
displayed.
12. Press the Enter key. The display will now read
0539, indicating that the computer is ready for
step 5.
13. A natural next step in the cycle might be a
dilution rinse.
a. Press the Cold and High keys to program a
cold fill to high level. The display will read
CH0539.
b. Press the Enter key. The display will read
M---S.
c. Enter the desired time for the computer to
allow the machine to fill to high level. Five
minutes is acceptable. Press key 5. The
display will read 5M-00S.
NOTE: If the machine does not fill in the amount of
time programmed, the FILL alarm will be
displayed.
14. Press the Enter key. The display will read
0639, indicating that the computer is ready for
step 6.
15. Next, program another wash step:
a. Press the Wash key and key 1 to program an
action with normal reversing. The display will
read W10639.
b. Press the Enter key. The display will read
M---S.
c. Now enter the step duration. Three minutes is
acceptable. Press key 3. The display will read
3M-00S.
16. Press the Enter key. The display will read
0739, indicating that the computer is ready for
step 7.