POST Messages
POST Message Description
00019501 Processor 1 is not functioning.
Action: Replace the primary microprocessor. (The Primary Microprocessor Error
LED on the system board will be on. See “System Board LEDs” on page 168 for
the location of the LED.)
If the problem persists, have the system serviced.
00019502 Processor 2 is not functioning.
Action: Replace the secondary microprocessor. (The Secondary Microprocessor
Error LED on the system board will be on. See “System Board LEDs” on page 168
for the location of the LED.)
If the problem persists, have the system serviced.
00019701 Processor 1 failed the built-in self test.
Action: Replace the primary microprocessor. (The Primary Microprocessor Error
LED on the system board will be on. See “System Board LEDs” on page 168 for
the location of the LED.)
If the problem persists, have the system serviced.
00019702 Processor 2 failed the built-in self-test.
Action: Replace the secondary microprocessor. (The Secondary Microprocessor
Error LED on the system board will be on. See “System Board LEDs” on page 168
for the location of the LED.)
If the problem persists, have the system serviced.
01298001 No update data for the processor 1 (the primary microprocessor).
Action: Update the system BIOS to a level that supports the microprocessors
installed in the server. See the “Getting Help Information” section of this
Server
Library
for information about obtaining updates from the World Wide Web.
01298002 No update data for processor 2 (the secondary microprocessor).
Action: Update the system BIOS to a level that supports the microprocessors
installed in the server. See the “Getting Help Information” section of this
Server
Library
for information about obtaining updates from the World Wide Web.
01298101 Bad update data for processor 1 (the primary microprocessor).
Action: Update the system BIOS to a level that supports the microprocessors
installed in the server. See the “Getting Help Information” section of this
Server
Library
for information about obtaining updates from the World Wide Web.
01298102 Bad update data for processor 2 (the secondary microprocessor).
Action: Update the system BIOS to a level that supports the microprocessors
installed in the server. See the “Getting Help Information” section of this
Server
Library
for information about obtaining updates from the World Wide Web.
I9990301 A hard disk drive error occurred.
Action: Have the system serviced.
I9990305 POST could not find an operating system.
Action: Install an operating system. If you have already installed the operating
system, check the drive startup sequence (see “Start Options” on page 28). If the
drive sequence is correct, run the diagnostic tests to verify that the hard disk drive is
functioning correctly. If there is a problem with the hard disk drive (such as a bad
sector), you might have to reinstall the operating system.
If you cannot reinstall the operating system, have the system serviced.
I9990650 AC power has been restored.
Action: No action is required. This message appears each time AC power is
restored to the server after an AC power loss.
Other Numbers POST found an error.
Action: Follow the instructions on the screen.
Chapter 6. Solving Problems 121