A SERVICE OF

logo

Before You Begin
Table 11. Netfinity 5000 Server Operating Specifications
Size
Depth: 560 mm (22.05 in.)
Height: 230 mm (9.06 in.)
Width: 420 mm (16.54 in.)
Weight
Typical server as shipped: 39 kg
(85.8 lb)
Environment
Air temperature:
Server on: 10° to 35° C
(50° to 95° F)
Altitude: 0 to 914 m (3000 ft.)
Server on: 10° to 32° C
(50° to 90° F)
Altitude: 914 m (3000 ft.) to
2133 m (7000 ft.)
Server off: 10° to 43° C
(50° to 110° F)
Maximum Altitude: 2133 m
(7000 ft.)
Humidity:
Server on: 8% to 80%
Server off: 8% to 80%
Maximum altitude: 2133 m
(7000 ft)
Electrical Input
Sine-wave input (50 to 60 Hz) is
required
Input voltage:
Low range:
- Minimum: 90 V ac
- Maximum: 137 V ac
High range:
- Minimum: 180 V ac
- Maximum: 265 V ac
Input kilovolt-amperes (kVA)
approximately:
- Minimum configuration as
shipped: 0.08 kVA
- Maximum configuration:
0.52 kVA
Total Power Available for Drives
Nominal Operating Current allowed:
+5 V dc line: 5.3 A
+12 V dc line: 5.0 A
Heat Output
Approximate heat output in British
Thermal Units (Btu) per hour:
Minimum configuration:
350 Btu (102 watts)
Maximum configuration:
860 Btu (251 watts)
Acoustical Noise Emissions Values
Sound power, idling
6.2 bel for open bay system
(no hard disk drives installed)
6.3 bel for system with one
hard disk drive installed)
Sound power, operating
6.2 bel for open bay system
(no hard disk drives installed)
6.3 bel for system with one
hard disk drive installed)
Sound pressure, idling
47 dBa for open bay system
(no hard disk drives installed)
48 dBa for system with one
hard disk drive installed)
Sound pressure, operating
47 dBa for open bay system
(no hard disk drives installed)
48 dBa for system with one
hard disk drive installed)
Chapter 5. Installing a Server in a Rack Enclosure 95