![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/d8/1d8ddec9-8608-430d-94d0-5735b30527c4/1d8ddec9-8608-430d-94d0-5735b30527c4-bg1f.png)
30
7.5.3. XFC-S
Use the following procedure to clean or replace the filter cartridge:
1. Unlatch the four (4) clamps that hold the collection bin to the filter assembly.
2. Discard contents of the collection bin if needed.
3. Loosen and remove the wing bolt that holds the filter cartridge in place.
4. Remove the filter cartridge from the assembly.
5. Use compressed air to clean the filter cartridge. Blow from the inside to the outside of
the filter cartridge. Make sure that the compressed air pressure is less than 100 PSI
(6.9 Bar) to keep from damaging the filter. Replace the filter cartridge if it shows
signs of wear.
6. Wipe down the gaskets on the filter cartridge and on the filter assembly where the
collection bin will meet.
7. Re-install the filter cartridge. Make sure the filter cartridge is properly seated in the
housing, and bolt it into the assembly.
8. Replace the collection bin and re-latch the clamps that hold it into place.
Spare Parts
Filter cartridge: ID A0571262