Installation
38970
18
NOTE: Some models come without an electrical
plug installed. If washer is not hard wired (refer to
Figure 15), a suitable plug that meets local
electrical standards, including earthing
requirements, must be installed. Refer to the
washer nameplate for proper voltage and Hertz the
washer is designed to operate on. Refer to
Figure 51.
100 Volt/50 Hertz
The washer is designed to be operated on a separate
polarized three-wire, earth (grounded) 100 Volt,
50 Hertz, single-phase electrical circuit protected by a
15 ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT WHEN THE WASHER IS
OPERATING.
100 Volt/60 Hertz
The washer is designed to be operated on a separate
polarized three-wire, grounded 100 Volt, 60 Hertz,
single-phase electrical circuit protected by a
15 ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT WHEN THE WASHER IS
OPERATING.
240 Volt/50 Hertz
The washer is designed to be operated on a separate
polarized three-wire, earth (grounded) 240 Volt,
50 Hertz, single-phase electrical circuit protected by a
10 ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT WHEN THE WASHER IS
OPERATING.
240 Volt/60 Hertz
The washer is designed to be operated on a separate
polarized three-wire, grounded 240 Volt, 60 Hertz,
single-phase electrical circuit protected by a
10 ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT WHEN THE WASHER IS
OPERATING.
230 Volt/50 Hertz
The washer is designed to be operated on a separate
polarized three-wire, earth (grounded) 230 Volt,
50 Hertz, single-phase electrical circuit protected by a
10 ampere fuse, equivalent fusetron or circuit breaker.
DO NOT OPERATE OTHER APPLIANCES ON
THE SAME CIRCUIT WHEN THE WASHER IS
OPERATING.
Grounding Instructions
The washer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. The washer is equipped
with a cord having an equipment-grounding conductor.
Some models are also equipped with a three-prong
grounding plug. The washer must be plugged or hard
wired into an appropriate power source that is properly
installed and grounded in accordance with all local
codes and ordinances.
DO NOT modify the plug provided with the washer –
if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
If the laundry room’s electrical supply does not meet
the above specifications and/or if you are not sure the
laundry room has an effective ground, have a qualified
electrician or your local electrical utility company
check it and correct any problems.
Improper connection of the equipment-
grounding conductor can result in a risk
of electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the washer is
properly grounded.
W300
WARNING
Any disassembly requiring the use of
tools must be performed by a suitably
qualified service person.
W299
WARNING