RECESSED AREA/CLOSET
INSTALLATION INSTRUCTIONS
Check governing codes and ordinances.
This dryer may be installed in a recessed
area or closet.
PRODUCT DIMENSIONS
Location must be large enough to fully
open dryer door.
Confined or Recessed Area Installation
Exhausting the dryer outside is recom-
mended. The moisture and lint indoors
may cause:
Lint to gather inside and around the
dryer and be a fuel for a fire.
Moisture damage to woodwork, furni-
ture, paint, wallpaper, carpet, etc.
Housecleaning problems and possible
health problems.
Recessed installation that is not
exhausted outside must use Exhaust
Deflector Kit Part No. 3391278. This
kit is available at your local Sears store
or Sears Service Center.
Closet Installation
WARNING: To reduce the risk of fire,
this appliance must be exhausted
outdoors when installed in a closet.
NOTE: No fuel burning appliances
may be installed in the same closet
as a dryer.
271/2"
OlO
2?'-d
Front View Side View
(Door Not Shown) (Door Shownl
_(-**.51/z -
FrontView
(DoorWithVent)
MINIMUM INSTALLATIONSPACING. Closet installation MIJ_r be exhausted outside.
"Additional clearances for waft, door and floor moldings may be required. _' ctearaoce
is acceptable butnot recommended.
** Opening is minimum forcloset door. Louvered doorwith equivalent air
openings is acceptable.
*** Additional space is needed when external exhaust elbow is used• Can be 0" clearance
when house exhausting is lined up directly with dryer exhaust.
3"
3"
,,The installation spacing is in inches
and is the minimum allowable.
Additional spacing should be
considered for ease of installation
and.,servicing.
If closet door is installed, the
minimum air openings in top and
bottom are required. Louvered doors
with equivalent air openings in top
and bottom are acceptable.
Closet installation must be exhausted
outside. Other installations must use at
least the minimum dimensions indicated.
4 _
i