Kenmore 3405602 Clothes Dryer User Manual


 
36
III. MAKE FOUR-WIRE
ELECTRICAL CONNECTION
TO RECEPTACLE
Use a 4-wire power supply cord:
Electrical Shock Hazard
Turn power' supply off before
('onnecting cord.
Use a new 30-ampere power
supply cord.
Plug into a grounded outlet.
Failure to follow these instructions
(;an result indeath, fire, or
electrical shock.
Local codes may permit the use of
a U.L.-listed, 120/240-volt minimum,
30-ampere, dr_,er power supply cord
kit (pigtail). Power supply cord should
be "typeSRD or SRDT and be at least
fou="feet long. The wires that connect
to the dryer must end with ring terminals
or spade terminals with upturned ends.
NEUTRAL NEUTRAL
/ 3/4",U.L.-listed, (white)
J strainrelief \(_
prong wire (green) terminals
Four-wire power supply cord
(Mobile home or other
four-wire installations)
For mobile homes or other four-wire
inst,allations, the power supply cord
must have four, No.-10 copper wires
and match a four-wire receptacle
of I_!EMA Type 14-30R. The fourth
wire. (grounding conductor) must be
identified with a green cover or bare
copper wire and the neutral conductor
by a white cover.
Four-wire receptacle
(NEMA Type 14-30R)
Do not use an extension cord with
this dryer.
Do not connect plug end of power
supply cord into a live receptacle before
connecting power supply cord to dryer
terminal block.
GROUNDING INSTRUCTIONS
This appliance must be grounded.
In the event of malfunction or break-
down, grounding will reduce the risk
of electric shock by providing a path
of least resistance for electric current.
The power supply cord must be plugged
into an appropriate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
WARNING: Improper connection of the
equipment-grounding conductor carl
result in a risk of electric shock. Check
with a qualified electrician or serviceman
if your are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug on the power
supply cord. If it will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
STEP 1. Turn power supply off.
STEP 2. Remove hold-down screw
and terminal block cover.
Hold-downscrew Terminalblockcover