Heatcraft Refrigeration Products 2500018 Clothes Dryer User Manual


 
Table 9� Specications
1
Motor voltage 208-230/1/60; 1075 RPM
2
Motor voltage 208-230-460/3/60; 1140 RPM
NOTE: Model 008-010, 1-2; available in 115/1/60 voltage; model 024-133, 5-26 available in 575/3/60 voltage
12 Part # 2500018
Installation and Operations Manual
18”
22”
13/32” x 1/2” Slots
Unit legs are removable
from units installed
for horiziontal air
2”2”
31 1/4”
37 1/2”
27 5/8”
2 7/16”
9/16”
15 1/4”
7/16” Diameter Hole
8”
22”
Diagram 6� Dimensions for Models 008-016, 1-3
Condenser Specications
Model Dimensions
CFM
No.
Fans
Dia.
(in.)
Motor Data
Connections
(ODS)
Net Wt.
(lbs.)
WSS DVT FCB A B HP
1
FLA
1
HP
2
FLA
2
Inlet Outlet
008 001 1 2,400 1 18 1/4 2 3/8 3/8 96
009 —- 1.5 2,400 1 18 1/4 2 5/8 5/8 96
010 002 2 2,400 1 18 1/4 2 7/8 5/8 96
016 003 3 2,100 1 18 1/4 2 7/8 5/8 114
024 005 5 40 30 5,050 1 24 1/3 3.4 1/3 2.6/1.3 1-1/8 7/8 180
040 008 8 50 40 6,450 1 26 1/2 3.9 1/3 2.6/1.3 1-1/8 7/8 260
049 010 10 70 60 10,100 2 24 1/3 6.8 1/3 5.2/2.6 (2)1-1/8 (2)7/8 450
061 012 12 70 60 12,400 2 26 1/2 7.8 1/3 5.2/2.6 (2)1-1/8 (2)7/8 470
070 014 14 90 80 13,700 2 26 1/2 7.8 1/3 5.2/2.6 (2)1-1/8 (2)7/8 510
080 016 16 90 80 12,900 2 26 1/2 7.8 1/3 5.2/2.6 (2)1-3/8 (2)1-1/8 530
105 021 21 130 120 20,500 3 26 1/2 11.7 1/3 7.8/3.9 (2)1-5/8 (2)1-1/8 550
113 023 23 130 120 19,900 3 26 1/2 11.7 1/3 7.8/3.9 (2)1-5/8 (2)1-1/8 580
133 026 26 130 120 19,400 3 26 1/2 11.7 1/3 7.8/3.9 (2)1-5/8 (2)1-1/8 625
Figure 11. Model 008-040, 1-8
Figure 12. Model 049-080, 10-16 Figure 13. Model 105-133, 21-26
General Fan Layouts