Bosch Appliances WTL 5410 Clothes Dryer User Manual


 
17
Technical Data
WTA 3510: 88 lbs. (40 kg) – with packaging 199 lbs. (45 kg)
WTL 5410: 99 lbs. (45 kg) – with packaging 110 lbs. (50 kg)
22
1
/
4
’’
(565 mm)
23
5
/
8
’’
(600 mm)
33
1
/
2
’’ (850 mm)
adjusts to
34
1
/
2
’’ (876 mm)
Figure 12.
Electrical Requirements
The Bosch dryers should be CONNECTED TO AN 30A
INDIVIDUAL BRANCH CIRCUIT. North American
models have the following electrical rating:
Model
Volts Hertz Amperes Watts
(max.)
WTA
3510
208/240 60 13 3,100
WTL
5410
208/240 60 13 3,100
Check the rating plate on the dryer to make sure your
machine has this rating.
Choosing the Location
The dryer should not be installed:
l in an area exposed to dripping water or outside
weather conditions
l in an area where it (and in the case of the WTA 3510,
its exhaust duct) will come in contact with
combustible materials, such as curtains, drapes
or paper.
l in areas where water may freeze
l in an area where gasoline or other flammables are
kept or stored.
Check local codes before choosing a location. Some
codes do not permit installation of a clothes dryer in
a garage, closet, mobile home or sleeping area. Your
local building inspector should be able to advise you of
the codes in your area.
Minimum Installation Clearances
Alcove or Under
Counter
Closet
Sides 0’’ (00 mm) 0’’ (000 mm)
Top 0’’ (00 mm) 10’’ (250 mm)
Rear 1’’ (25 mm) 5’’ (125 mm)
Ventilation Requirements
Alcove or
Under
Counter
Closet
WTA
3510
Ensure air flow
of
112 cu.ft./min
(3,2 cu.m./min)
through dryer
Closet door must have
2 (louvered) openings,
each having a minimum
area of 60 sq. inches
(387 sq. cm.), located
3 inches (8 cm) from
bottom and top of door. *
WTL
5410
Ensure air flow
of
118 cu.ft./min
(3,3 cu.m./min)
through dryer
Closet door must remain
open during dryer
operation.
* A louvered door with equivalent air opening
is acceptable.
Flooring
The dryer should be installed on a level, solidly
constructed floor. DO NOT install the dryer on
a carpeted floor.