c. Flexible hoses or couplings must be used. The dryer vibrates slightly when it runs and this will cause the
steam coil connections to crack if they are hard piped to the supply and return mains.
d. Shutoff valves for each dryer should be installed in the supply line, return line, and drip trap return line.
This will allow the dryer to be isolated from the supply main and the return main if the dryer needs
maintenance work.
e. Install an inverted bucket steam trap and check valve at least 12-inches (30.48 cm) below the steam coil
as close to the coil as possible.
1) An inverted bucket steam trap with capacity of 1,400 pounds (635.03 kg) of condensate per hour @
125 PSI (862 kPa)
is required for each unit.
f. A 3/4-inch (19.05 mm) vacuum breaker should be installed for each unit in the piping. This will prevent
the condensing steam from causing a vacuum inside the coil and possibly damaging the coil.
g. The supply line and the return line should be insulated. This will save energy and provide for the safety
of the operator and maintenance personnel.
h. Water pockets in the supply line, caused by low points, will provide wet steam to the coil possibly causing
steam coil damage. ALL horizontal runs of steam supply piping should be pitched 1/4-inch (6.35 mm)
for every 1 foot (0.31 meters) back towards the steam supply header causing the condensate in the line
to drain to the header. Install a bypass trap in any low point to eliminate wet steam.