American Dryer Corp. AD-50 Clothes Dryer User Manual


 
113610-1 www.amdry.com 21
!
!
Note
To stop the dryer, open main door or press the
“PAUSE” key. Continuation of the cycle will
resume only after the door has been closed and any of
the 3 temperature selection is pressed.
Mechanical Drop/Rotary Coin Meter
or Slide Coin Meter
Insert coin and turn knob (rotary type meter) or for slide meter
unit, push in coin chute.
Select temperature.
Push the “Start” button.
To stop the dryer, open the main door.
Non-Coin Models
Microprocessor Controller (Computer)
The L.E.D. display reads “READY” (no cycle in progress).
Press the letter on the keypad corresponding to the cycle
desired (i.e., key “D”).
The dryer will then start (i.e., blower, tumbler, and heat).
The L.E.D. display will read MANUAL DRYING CYCLE D,
00:00 MIN REMAIN.
Note
The dryer can be stopped at any time by pressing
the “STOP/CLEAR” key, at this time the dryer will
go into a cycle pause. If the “STOP/CLEAR” key is
pressed again at this point, the cycle that was in progress
will be cancelled and returned to the “READY” state.
When the programmed drying time has expired, the Phase 7
non-coin microprocessor controller (computer) will proceed
into the cool down cycle.
Once the cool down cycle begins at the end of the heat cycle,
the L.E.D. display will read COOL DOWN TEMP ___/___
MINUTES remaining. At the end of the heat cycle, the dryer
will shut off the heat and continue the fan and tumbler until
the cool down time or temperature is reached.
Mechanical Timer
Turn drying timer knob for a time of 20 minutes.
Select “High Temp.”
Push “Push to Start” button.
To stop the dryer, open the main door.
Shutdown Instructions _______________
If the dryer is to be shutdown (taken out of service) for a
period of time, the following must be performed:
Discontinue power to the dryer either at the external disconnect
switch or the circuit breaker.
Discontinue the heat supply:
Gas Models – Discontinue the gas supply.
SHUT OFF external gas supply shutoff valve.
SHUT OFF internal gas supply shutoff valve located in the
gas valve burner area.
Steam Models – Discontinue the steam supply.
SHUT OFF external (location furnished) shutoff valve.
SHUT OFF internal steam valves in the supply lines and the
return lines.
NOTES _____________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________
____________________________________________________________