American Dryer Corp. AD-170SE Clothes Dryer User Manual


 
43
B. ADJUSTMENTS
7 Days After Installation and Every 6 Months Thereafter
Inspect bolts, nuts, screws (bearing set screws), non-permanent gas connections (unions, shut-off valves,
orifices, and grounding connections). Motor and drive belts should be examined. Cracked or seriously
frayed belts should be replaced. Tighten loose V-belts when necessary. Complete operational check of
controls and valves. Complete operational check of ALL safety devices (door switch, lint drawer switch,
sail switch, burner and hi-limit thermostats).
C. LUBRICATION
The motor bearings, idler bearings, and tumbler bearings are permanently lubricated.
NO LUBRICATION IS NECESSARY.1.
90 Days
Re-grease the two (2) 1-3/8-inch bearings that support the impellor/fan shaft. Use
Shell Alvania #3 grease
or its equivalent. Impellor/fan shaft bearings should be lubricated.
Check to make sure that the set screws on the impellor/fan shaft bearing are tight.
Remove lint from around basket (tumbler), drive motors, and surrounding areas. Remove lint from gas
valve burner area with a dusting brush or vacuum cleaner attachment.
NOTE: To prevent damage, avoid cleaning and/or touching ignitor/flame-probe assembly.
Remove lint accumulation from inside control box and at rear area behind control box.