American Dryer Corp. AD-170SE Clothes Dryer User Manual


 
34
J. PREOPERATIONAL TESTS
ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test
should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or
due to marginal location (installation) conditions.
1. Turn on electric power to the dryer.
2. Make sure the main door is closed and the lint drawer is securely in place.
3. System controls operational test -- to start the dryer ...
a. Microprocessor (computer) controls ...
1) Display will read "FILL".
2) Press the "E" (preprogrammed) cycle key on the touch pad of the keyboard.
3) L.E.D. display will quickly read..."Ld30", "Lc04", and "F180" (unless special programs requested).
These codes mean that the dryer is in the timed mode and will operate with heat of 180 F (Fahrenheit)
for 30 minutes drying time and have a 4-minute cool down period.
4) Dryer will now start and the L.E.D. display will read "Dr30" (dry mode for 30 minutes) and count
down in minutes.
NOTE: The dryer can be stopped at any time by opening main door or by pressing the
"CLEAR/STOP" key. To restart the dryer, press the "ENTER/START" key or
preprogrammed cycle key(i.e., "E").
NOTE: Pressing touch pad key "A," "B," "C," "D," and "F" will also start the dryer.
The six (6) preprogrammed drying cycles ("A" through "F") have been stored in
the microprocessor (computer's) memory. Refer to the computer programming
manual supplied with dryer for these preprogrammed cycles.
b. Timer (manual) controls system operational test -- to start the dryer ...
1) Turn "HEAT" timer knob (clockwise) for a time desired (i.e., 1 minute to 60 minutes).
2) Make the desired temperature selection (i.e, "HIGH," "LOW," or "PERM PRESS") at the rocker
switch.
3) Press "PUSH TO START" switch button and the dryer will start.
4) To stop the dryer, open the main door.