American Dryer Corp. AD-170SE Clothes Dryer User Manual


 
61
SECTION VIII
REVERSING TIMER SPIN/DWELL ADJUSTMENTS
Timer models have an electric reversing timer in the electric service box which is located in the upper left rear
area of the dryer.
Both the Dwell (stop) Time and basket (tumbler) Spin Time are adjustable by mode selection switches located on
the electronic timer (as noted in the illustration below).
Timing Legend
Spin Time
Switch Position Number 1 2 3 4 5
Time in Seconds* 30 60 90 120 150
Dwell (Stop) Time
Switch Position Number 1 2 3 4 5
Time in Seconds* 5 6 8 10 12
* Values shown are +/- 1 second.