American Dryer Corp. AD-170SE Clothes Dryer User Manual


 
56
STEAM MODELS
1. Failed lint chamber sensor bracket basket (tumbler) hi-limit switch circuit.
2. Failed temperature selection switch or circuit.
3. Failed temperature cycle thermostat (try another selection).
4. Failed heat timer.
I. No heat...voltage is confirmed at heating unit (i.e., Gas Model DSI module or Steam Model
damper system pneumatic solenoid)...
GAS MODELS
1. Fault in Direct Spark Ignition (DSI) ignition system...
a. Ignitor sparks but no ignition and Direct Spark Ignition (DSI) module locks out (RED L.E.D. indicator
light stay on)...
1) Ignitor probe assembly is out of adjustment or has failed.
2) Severe air turbulance.
3) Failed Direct Spark Ignition (DSI) module.
4) Failed gas valve.
b. Ignitor sparks, burner lights but goes off right away...
1) Direct Spark Ignition (DSI) ignitor out of adjustment...or has failed.
2) Sail switch is fluttering...
a) Lint drawer screen is dirty.
b) Restriction in exhaust duct work.
c. Ignitor does not spark and Direct Spark Ignition (DSI) module locks out (RED L.E.D. indicator light
stays on)...
1) Fault in high voltage (HV) wire...break or loose connection.
2) Failed ignitor probe assembly.
3) Failed Direct Spark Ignition (DSI) module.