American Dryer Corp. AD-170SE Clothes Dryer User Manual


 
13
C. DRYER ENCLOSURE REQUIREMENTS
Even though a 12-inch clearance is acceptable, it is recommended that the rear of the dryer be positioned
approximately two (2) feet (24-inches) from the nearest obstruction (i.e., wall) for ease of installation,
maintenance, and service. Bulkheads and partitions should be made from noncombustible materials. The
clearance between the bulkhead header and the dryer must be a minimum of 4-inches and must not extend
more than 4-inches to the rear of the dryer front. A 2-inch clearance is required between the bulkhead facing and
the top of the dryer.
NOTE: Bulkhead facing should not be installed until after dryer is in place. Ceiling area
must be located a minimum of 6-inches above the dryer top console (module) for
gas models and 18-inches for steam models.
Even though a minimum of 6-inches above the dryer console (module) is acceptable
for gas models and 12-inches above the dryer console (module) is acceptable for
steam models, a clearance of 12 inches or more (for gas models) and 18-inches or more
(for steam models) is suggested for ease of installation and service.
NOTE: When fire sprinkler systems are located above the dryers, a minimum of 18-inches
above the dryer console (module) is required. Dryers may be positioned side wall
to side wall; however, 1 or 2-inches is suggested between dryers (or wall) for ease of
installation and maintenance. Allowances must be made for the opening and closing
of the control and lint door.