American Dryer Corp. AD-170SE Clothes Dryer User Manual


 
29
H. STEAM INFORMATION
It is your responsibility to have ALL steam plumbing connections made by a qualified professional to assure that
the installation is adequate and conforms with local and state regulations or codes.
IMPORTANT: Failure to comply with the requirements stipulated in this manual can result in
component failure which will
VOID THE WARRANTY.
NOTE: The M-170 is manufactured with a pneumatic (piston) damper system which
requires an external supply of clean, dry, regulated air (80 psi +/- 10 psi). Refer to
Steam Damper Air System Connections, Section H, item 3.
1. STEAM COIL PH LEVEL
The normal PH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For steel
type steam coils the PH level must be maintained between a value of 9.5 to 10.5. These limits are set to limit
the acid attack of the steam coils.
IMPORTANT: Coil failure due to improper PH level will VOID THE WARRANTY.
2. STEAM REQUIREMENTS - High Pressure
Inlet ---------1-1/2" supply line connection -- qty. one (1) at top manifold.
Return ------ 1-1/2" return line connection --- qty. one (1) at bottom manifold.
* Minimum operating pressure for optimum drying results.
3. INSTALLATION INSTRUCTIONS
To insure that an adequate supply of steam is provided, be sure that the steam supply and steam return lines
are sized and laid out as stipulated in this manual. Inadequate steam supply and steam return lines or
improper steam plumbing will result in poor performance and can cause component failure. Clean, dry,
regulated steam must be provided to the dryer.
IMPORTANT: Steam coil failure due to water hammer by wet steam will ...
VOID THE WARRANTY.
Operating Steam Pressure
Maximum 125 psig
Minimum 100 psig*
Heat Input (Normal Load) 19 Bhp
Consumption (approximate) 725 lbs/hr