I M P O R T A N T
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR TIMER OR PHASE 5 WITHOUT HEAT FAULT
(ELECTRIC or STEAM)
This dryer was manufactured with a burner and tumbler/lint chamber manual reset burner hi-limit thermostat.
If the manual reset thermostat is open prior to the start of the drying cycle, or during the cycle, the dryer will not
recognize the open state of the burner hi-limit thermostat and will start or continue through the drying cycle with
no heat. The applicable manual reset hi-limit must be reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow or improper heating
unit operation.
The location of the burner manual reset hi-limit switch is in the lint chamber area.
WARNING: Discontinue electrical power to the dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a
lint chamber hi-limit thermostat
which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N: 114501