American Dryer Corp. AD-115ES Clothes Dryer User Manual


 
61
SECTION IX
BURNER and LINT (TUMBLER) CHAMBER
MANUAL RESET HI-LIMIT INSTRUCTIONS
I M P O R T A N T
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR TIMER OR PHASE 5 WITHOUT HEAT FAULT
(GAS MODELS ONLY)
This dryer was manufactured with a burner and tumbler/lint chamber manual reset burner hi-limit thermostat.
If either manual reset burner hi-limit thermostat is open prior to the start of the drying cycle, or during the cycle,
the dryer will not recognize the open state of the burner hi-limit thermostat and will start or continue through the
drying cycle with no heat. The applicable manual reset hi-limit thermostat must be reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow or improper burner
oven operation.
The location of the burner manual reset hi-limit switch is on the right side of the burner box.
IMPORTANT
This dryer is equipped with a burner
hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N: 114093