Alliance Laundry Systems TMB1276C Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Diagnostics
70444801
34
Inputs Outputs Menu
When the Inputs Outputs Menu is accessed through
the Diagnostic Menu, the user can manually turn on
outputs. The user can scroll through the outputs using
any of the arrow keys, the cursor is indicated by
flashing the active output on the screen. The user must
“setup” the outputs to be turned on. The keypad
is used to select individual outputs to be turned on or
off. After the keypad is pressed the control will
turn the selected outputs on and display the text
“RUNNING”. The outputs cannot be selected until
the keypad is pressed. The text “RUNNING” is
no longer displayed. The screen will still show the
selected outputs on the screen and the user can again
select outputs to be turned on or off. If the or
keypad is pressed at any time during this test,
the control will turn off all outputs if the test is running
or return to the previous screen if the test is not
running.
If the Inputs Outputs Menu is accessed through the
Run Diagnostic Menu (pressing the keypad
during a running cycle) the menu shows only what is
turned on and off as the cycle runs. Refer to Figure 43.
Abbreviations for the Inputs and Outputs are defined
in the following table:
Table 4
TMB1425R
Figure 43
Inputs Outputs
Outputs:
Intputs:
RPM:25 Moisture:30%
DM FM FW RV HT EA IR
DR LD AFS FCRS FCLS CL SL1 SL2 IL
RS DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8
30:29
Temp:180 F
Inputs
DR Loading Door
LD Lint Door
AFS Airflow Switch
FCRS Fan Motor Contactor Switch
FCLS Fan Motor Centrifugal Switch
CL Cabinet High Limit
SL1 Store 1 High Limit
SL2 Store 2 High Limit
IL Ignition Lockout
RS Rotation Sensor
DIP1 Dip Switch 1
DIP2 Dip Switch 2
DIP3 Dip Switch 3
DIP4 Dip Switch 4
DIP5 Dip Switch 5
DIP6 Dip Switch 6
DIP7 Dip Switch 7
DIP8 Dip Switch 8
Temp Temperature
RPM Rotations per Minute
Moisture Moisture Level
Outputs
DM Damper Motor
FM Fan Motor
FW Forward Contactor
RV Reverse Contactor
HT Heater
EA External Alarm
IR Ignition Reset