Operation Modes
General Modes of Operation
In each mode of operation, the user may press keypads
or communicate with the control to change the
displayed menu.
Power-up Mode
The control enters this mode at power-up. After the
control completes operation in the Power-up Mode it
will enter Idle Mode. The display is blank during
Power-up Mode.
Idle Mode
The control is ready for operation in Idle Mode.
Control can display different menus depending on user
input (keypad press, opening or closing the loading
door, or PDA communication). If there is no user input
for one minute, control will turn off the LCD
backlight. The control will light when there is user
input. If there is no user input for 10 minutes, the
display will go blank.
If the control is in Idle Mode, Cycle Menu is
displayed, loading and lint door closed, and the
keypad is pressed, control will enter Run Mode.
Run Mode
The Control enters Run Mode during a cycle. The
Display shows machine cycle time remaining, the
current cycle type, segment, temperature, and
graphical indicators. Loading and lint doors are closed
during Run Mode. Press keypad to stop cycle
and enter Pause Mode. Press keypad to enter
Run Diagnostic Menu. Control enters Pause Mode if
loading or lint door opens. Press to Rapid
Advance.
Rapid Advance Mode
If the Rapid Advance Option is enabled, the user can
advance a running machine cycle by pressing the
keypad. In a Time Dry cycle, pressing the
keypad will decrease the remaining time by one
minute. Pressing and holding the keypad will
decrease the remaining time by four minutes per
second until the end of the cycle.
In the Auto-Dry and Moisture Dry cycles, pressing the
keypad will advance the cycle to the next
enabled segment. Note that Auto-Dry cycles only have
one programmable segment.
In the Cool Down segment, pressing the keypad
will decrease the remaining time by one minute.
When the cycle is completed, the audit counter, Total
Rapid Advance Cycles is incremented rather than the
Total Machine Cycles audit counter. In addition this
cycle is recorded in the audit list “Last 25 Machine
Cycles Completed”. If the Rapid Advance Option is
disabled preventing a manual Rapid Advance, the user
may still execute a Rapid Advance using the PDA or
PC. Refer to UniLinc PC and PDA Application User
Instructions for additional information on using a
PDA or PC to Rapid Advance a cycle.
Pause Mode
If keypad is pressed or the loading or lint door is
opened while in Run Mode, control enters Pause
Mode.
If the door is opened then closed, the control will
prompt the user to press to resume the cycle.
If is pressed while already in Pause Mode, the
control will enter End of Cycle Mode.
Error Mode
This mode will be entered to display all fatal machine
errors.
Communication Mode
This mode is entered whenever the control is
communicating with a PDA or a network. Refer to
UniLinc PC and PDA Application User Instructions.
Cool Down Mode
The control enters the Cool Down Mode after the heat
segment of the cycle is completed or fatal error occurs.
The control turns the heater off and for steam heated
units turns the damper motor on. The cool down
segment will end once the cool down temperature has
been reached or the programmed cool down time
expires, which ever happens first.