Alliance Laundry Systems TMB1276C Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
UniLinc Identification
9
70444801
End of Cycle Mode
The control enters End of Cycle Mode after the cool
down segment is finished. The display will show a
graphic prompting the user to open the loading door. If
the door has not been opened or a keypad has not been
pressed after two minutes, the machine will enter
Extended Tumble Mode. This mode is exited when the
door is opened or a
or keypad is pressed.
The control will then return to Idle Mode.
Extended Tumble Mode
The Extended Tumble Mode has two portions. The
Anti-Wrinkle Tumble is entered two minutes after the
cycle has ended if the door is not opened. The cylinder
will tumble for 30 seconds every two minutes for up to
one hour.
If the door hasn’t been opened and no keys have been
pressed one hour after the Anti-Wrinkle Tumble has
ended, the control increments the Anti-Wrinkle Time
Exceeded audit counter and enters Delayed Tumble.
The cylinder will tumble for two minutes every 60
minutes for up to 18 hours.
Reversing Mode (reversing models only)
Models equipped with the reversing feature will rotate
in the forward direction, pause, rotate in the reverse
direction and then pause for programmable times and
segments of the cycle. Factory default reversing rotate
time is 120 seconds and reversing stop time is 6
seconds for all cycles with reversing enabled.
Entering Diagnostic Mode From Idle Mode
When entered from the Idle Mode, the control will be
running a test selected by the user via keypad presses
or communication with a device. The diagnostic tests
available from the Idle Mode are the Test Cycle and
Inputs Outputs Menus.