Dryer Exhaust Requirements
Exhaust System Materials
Exhaust system materials are not supplied with the
unit.
Exhaust duct must be 102 mm (4 inches) in diameter
having no obstructions. Rigid metal duct is
recommended. Non-combustible flexible metal duct is
acceptable. Do not use plastic or thin foil ducting,
because it contributes to poor drying performance and
collects lint, which can lead to a fire hazard.
Never install flexible duct in concealed spaces, such as
a wall or ceiling.
DO NOT use sheet metal screws on exhaust pipe joints
or other fastening means which extend into the duct
that could catch lint and reduce the efficiency of the
exhaust system. Secure all duct joints with duct tape or
pop-rivets.
NOTE: Kits described above are optional exhaust
system materials available at extra cost.
.
Figure 26
A clothes dryer produces combustible
lint. To reduce the risk of fire and
combustion gas accumulation the dryer
MUST be exhausted to the outdoors.
W116
To reduce the risk of fire and the
accumulation of combustion gases, DO
NOT exhaust dryer air into a window well,
gas vent, chimney or enclosed,
unventilated area, such as an attic, wall,
ceiling, crawl space under a building or
concealed space of a building.
W045
To reduce the risk of fire, DO NOT use
plastic or thin foil ducting to exhaust the
dryer.
W354
WARNING
Description Kit Part No.
May Be
Obtained
Locally
Exhaust Duct
102 mm (4 in.) Dia.
Not Available Yes
Flexible Metal Duct
102 mm (4 in.) Dia.
521P3 Yes
Weather Hoods, with
hinged dampers
102 mm (4 in.)
Not Available Yes
Directional Exhaust
Kit
528P3 No
Tape Not Available Yes
H312I
H312I
DO DON’T