© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
68 M414545
ENERGY SAVING TIPS
1. Install the tumbler so that short, straight venting can
be used. Turns, elbows and long vents tend to
increase drying time. Longer dry time means the use
of more energy and higher operating costs
.
2. Operate tumbler using full-size loads. Overloading
uses extra energy. Very small loads waste energy.
3. Dry lightweight fabrics separately from heavy
fabrics. Less energy will be used and drying results
will be more even if the fabrics being dried are of
similar weight.
4. Clean the lint screen after each eight hour shift. A
clean lint screen helps give faster, more economical
drying.
5. Do not open the loading door while drying. Warm air
will escape into the room.
6. Unload the tumbler as soon as the cylinder stops or
when LOAD READY light illuminates.
IMPORTANT: The input ratings shown on the serial
plate are for units that are being operated at
elevations up to 2,000 feet (610 m). If the tumbler is to
be operated above 2,000 feet (610 m), contact
distributor for proper gas orifices for your altitude.
SERVICE SAVERS
The following are some of the most common problems,
along with the solutions, that occur with a tumbler.
Before contacting the Service Department, perform these
procedures:
TUMBLER WON’T START
1. Is the loading door completely closed?
2. Is the drying timer in an OFF position?
3. Has the PUSH TO START knob been depressed for
three seconds?
4. Has a main fuse opened or is a main circuit breaker
tripped?
TUMBLER WON’T HEAT
1. Is the Gas Shut-off Valve on the tumbler in the OFF
position?
2. Is the tumbler in the cool down mode?
3. Is the lint screen clogged?
4. Is the airflow sufficient?
CLOTHES ARE NOT SATISFACTORILY DRY
1. Was enough heating time allocated for the load?
2. Is the lint screen clogged.
3. Is the exhaust duct to the outside clean and not
blocked?
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be reconnected
to ensure that the tumbler is properly grounded.
W002
WARNING