Alliance Laundry Systems 000 BTU Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
66 M414545
MONTHLY
LUBRICATION
Motor bearings, idler housing bearings and trunnion
bearings are pre-lubed sealed bearings and require no
lubrication.
LINT REMOVAL
1. Remove the exhaust duct from the exhaust thimble
and remove lint. If excessive lint is evident at the
thimble, further disassemble the duct work and
remove lint.
2. On Energy Saver Gas Models:
Remove the cleanout cover at the bottom of the
vertical duct and clean out lint.
EVERY THREE MONTHS
LINT REMOVAL
1. Clean the lint and any other foreign materials from
the air vents located on the front and back of the drive
motor. The drive motor is air cooled and if the air
vents become clogged, the motor will overheat and
the internal thermal overload protector will cycle off.
2. Steam Models: Check the steam coils and remove
any lint buildup and/or replace air filter in the coil fin
area. This can be accomplished by using compressed
air or by fabricating a comb that can be pulled across
the fin area of the coil.
3. Exhaust ducts should be periodically inspected to
ensure there has been no buildup of lint which could
obstruct the airflow.
4. Inspect the dryer area to make sure nothing is
obstructing the flow of combustion and ventilation
air.
5. Remove front panel and clean any lint buildup.
BELT TENSION
Check belt tension and adjust if needed. Refer to
appropriate section.
EVERY SIX MONTHS
OVERALL CHECK
Check the tumbler over thoroughly for loose nuts, bolts
and screws, and for loose gas, steam and/or electrical
connections.
GAS CONNECTIONS: (Unions, flared tube fittings)
Check for leakage that might be caused by vibration. Use
a mild soap solution. DO NOT USE A FLAME AT
ANY TIME TO CHECK FOR GAS LEAKS.
ELECTRICAL CONNECTIONS: Electrical service and
grounding connections should be examined for proper
tightness.
To reduce the risk of serious injury or
death, disconnect the power to the
tumbler before performing this operation.
W080
WARNING
To reduce the risk of serious injury or
death, disconnect power to the tumbler
before performing these operations.
W081
WARNING
To reduce the risk of serious injury or
death, disconnect the power to the
tumbler before performing this operation.
W080
WARNING