14
Moisture Control Switch-ON
Moisture Control Thermostat-MAXI-
MUM TEMPERATURE
Load Switch-OFF
Unload Switch-OFF
Fan Switch-OFF
Burner Switch-OFF
Out of Grain Timer-8 MINUTE
Load Delay-30 SECONDS
Unload Delay-30 SECONDS
Metering Roll Speed-LOW AND
HIGH SPEED SETTINGS PUT
ON ZERO
Dry Timer-60 MINUTE
Cool timer-20 MINUTE
Unload timer-10 SECONDS
Mode Switch-CONTINUOUS FLOW
DRYER PRE START CHECKS
PRE SEASON INSPECTION
INSPECT THE METERING
ROLLS
Open all metering roll access
doors and inspect each compart-
ment for any bolts, nuts or other for-
eign material, that may cause pos-
sible jamming of the metering rolls.
Before the dryer is filled, thoroughly
inspect the unit and check the op-
eration of the dryer as follows.
SET CONTROL SWITCHES
BEFORE ATTEMPTING TO
OPERATE THE DRYER MAKE
SURE ALL SAFETY SHIELDS
ARE IN PLACE, ALL BOTTOM
CLEANOUT AND REAR
ACCESS DOORS ARE CLOSED
AND ALL PERSONNEL ARE
CLEAR OF THE DRYER
The Maxon safety shut off valve.
FUEL CHECK
POWER START BUTTON
Push the DRYER START button,
and all the selector switches on the
control panel will be activated.
ELECTRICAL POWER
Turn ON the electrical power sup-
ply to the dryer, set all circuit break-
ers to ON, including the safety dis-
connect handle mounted on front
of the dryer's power panel.
CONTROL POWER
SWITCH
Turn the CONTROL POWER switch
to ON. The switch will light up. A
copyright message, model number,
total running time in hours and min-
utes, current date and time will ap-
pear. At this point the controller will
lock out all other dryer functions.
Once the date and time appear,
press RESET and the dryer will per-
form its safety circuit check. If a fault
is found, the cause will be displayed
on the LCD. If all are found safe, the
controller will supply power to the
electronic fuel shut- off valve (if
so equipped) and the DRYING
MODE switch will light up, indicating
that the dryer is ready to be started.
If using LP gas, make sure the tank
has plenty of fuel and that the tank
does not have a regulator mounted
to it. If using natural gas, make sure
an adequate supply is available.
If using LP gas, slowly OPEN
the main fuel supply valve at the
tank. If using natural, gas turn ON
the valve along the supply line.
Then, OPEN the electronic shut off
valve (Maxon valve), if so equipped,
or OPEN the manual shut off valve
on the dryer to allow fuel flow to the
dryer. Inspect all gas lines and con-
nections for possible leaks.
Any gas leaks need to be
fixed immediately!