DRYER CONTROL PANEL
SETTING THE DRY (16),
COOL (17) AND UNLOAD
(18) BATCH TIMERS
ELECTRONIC
MONITORING CONTROL
SYSTEM (14)
Figure 2: The Airtream Electronic Monitoring Control System
These switches are used to set the
cycle times in the STAGED BATCH
DRYING MODE only. The DRYING
MODE switch must be in the
STAGED BATCH position. The cur-
rent settings on these three TIMERS
are displayed directly above each
TIMER button. To change the set-
ting of these TIMERS follow these
instructions:
1. Press the DRY, COOL or UN-
LOAD TIMER button.
2. Press the MODIFY button.
3. Press the INCREASE or DE-
CREASE button to adjust the
settings.
4. Press the ENTER button.
During operation the remaining
time on each TIMER is displayed on
the screen. If the power goes out or
If the dryer runs out of grain while
the LOAD AUGER switch is in the
AUTO position, the OUT OF GRAIN
TIMER automatically shuts OFF the
dryer after the period of time preset
on the TIMER. When pressed, the
display will show the amount of time
left on the TIMER and the percent-
age of time the last load expended.
A second screen will appear show-
ing the TIMER'S setting and will al-
low the operator to modify it as de-
scribed for setting the BATCH TIM-
ERS.
SETTING THE OUT OF
GRAIN TIMER (19)
Turn the CONTROL POWER switch
to ON. The monitor will display a
copyright message and model num-
ber, total running time in hours and
minutes and the current time and
date. To activate the controller press
the RESET button.
TURNING ON THE
ELECTRONIC
MONITORING CONTROL
SYSTEM USING THE
RESET BUTTON (15)
The Electronic Monitoring Control
System (Figure 2) controls all tim-
ing functions and safety circuit
checks. It is designed to simplify
dryer operation by providing printed
messages and warnings on its liq-
uid crystal display (LCD).
if the dryer is stopped, these times
are saved by the controller. When
the dryer is restarted the TIMERS
will continue timing down. The TIM-
ERS will return to their initial settings
by pressing the RESET button.