ADC ML-96 Washer User Manual


 
49
c. If no voltage is present at J7 9-pin connector no. 4 to ground, but voltage is present at no. 3 to ground. The
problem is a faulty switch, wires or termination between J7 to J8 and J8 to the lint switch no. 20 and 21.
d. If no voltage is present at J7 9-pin connector no. 3 to ground, then voltage should not be present at no.
5 to ground. Replace the board.
6. Main Door Condition
NOTE: Make sure main door and lint door are closed. Also, if checking either switch, the plunger
must be depressed.
a. Check L.E.D. (light emitting diode) input light MAIN on the component side of the computer. If the
light is on, replace the computer.
b. Check voltage (24 VAC) from J7 9-pin connector no. 5 to ground. If voltage is present, check no. 6 to
ground. If voltage is present, replace board.
c. If no voltage is present at J7 9-pin connector no. 6 to ground, but voltage is present at no. 5 to ground. The
problem is a faulty switch, faulty wires or terminations J7 to J8. J8 to J5 and J5 to main door switch no.
31 and no. 32.
7. No Heat drive and blower motors run, display reads normal (gas models).
a. Check L.E.D. (light emitting diode) input light HT1 on the component side of the computer. If the light
is on replace the board.
b. If the L.E.D. (light emitting diode) input light HT1 on the component side of the computer is on and
there is no voltage to the HSI (Hot Surface Ignition) module w the display will read BURNER CONTROL
FAIL. The problem is faulty wires or terminations between microprocessor and HSI (Hot Surface
Ignition) module.
c. If voltage is present on the HSI (Hot Surface Ignition) module w to ground. Check voltage at the gas
valve if voltage is present across the two yellow wires at the gas valve and the gas supply is on then the
fault is that of the gas valve.
8. Microprocessor (Computer)
a. Replace the temperature sensor underneath the tumbler (basket) on a bracket (the bullet shaped device).
b. If it still reads TEMP SENSOR FAIL CHECK TEMP SENSOR FUSE, unplug J3 4-pin connector from
the temperature sensor bracket. Also, unplug the microprocessor J14 4-pin connector from the computer
board. Take a continuity reading from J14 no. 1 to J3 no. 1, then from J14 no. 2 to J3 no. 2.
If there is no continuity, check for break in wire, a short to the ground, loose terminations, or even replace
the wire.
If there is continuity, computer board is faulty.