4. Remove the two (2) screws securing the computer to the computer panel. Remove the computer by pulling
the other two (2) corners off the clinch studs.
5. Install new computer by reversing this procedure.
Keyboard (Touchpad) Label Assembly Replacement
1. Discontinue electrical power to the dryer.
2. Unplug keyboard (touchpad) ribbon from rear of the computer.
3. Slowly peel off and remove keyboard (touchpad) label assembly from control panel.
4. Peel paper backing off new keyboard (touchpad) label assembly.
5. Holding the new keyboard (touchpad) label assembly close to the panel, insert the keyboard (touchpad) ribbon
through the rectangular slot in the control panel. Align label assembly into position by matching the red
viewing window on the label to the rectangular cutout in the panel and gently press into place.
6. Connect keyboard (touchpad) ribbon to the computer.
7. Reestablish electrical power to the dryer.
Microprocessor Temperature Sensor Probe Replacement
1. Discontinue electrical power to the dryer.
2. Remove perforated panel from tumbler (basket).
3. Remove microprocessor sensor bracket assembly from dryer.
a. Disconnect sensor bracket harness connector.
b. Loosen the two (2) Phillips head screws which secure bracket
assembly to dryer and remove bracket from dryer.
NOTE: DO NOT remove screws.
4. Disassemble sensor probe from bracket assembly by removing the top push-on fastener securing the probe
from bracket. Use a small screwdriver to slowly pry the fastener off.
5. Disconnect the two (2) orange wires from the high heat (225º F [107º C]) thermostat, and remove modular
bracket connector, wires, and probe from bracket assembly.
6. Install new sensor probe assembly (ADC P/N 880252) by reversing procedure.
7. Reestablish electrical power to the dryer.
NOTE: If, when electrical power is reestablished, the computer display reads TEMP SENSOR FAIL
CHECK TEMP SENSOR FUSE, check for a loose connection in the wiring.