ADC ML-96 Washer User Manual


 
39
4. L.E.D. DISPLAY INDICATOR NUMBER 4
a. On Indicator:
1) This indicator dot is on whenever a cycle is in progress. Additionally, when the Anti-Wrinkle
program is active, the indicator dot will be on whenever the Phase 6 OPL microprocessor controller
(computer) is in the Guard On Time program.
5. L.E.D. DISPLAY INDICATOR NUMBER 5
a. Air Jet Circuit - OPTIONAL
1) This indicator dot is on at the end of the dryer cycle for approximately 60 seconds.
C. PHASE 6 OPL MICROPROCESSOR CONTROLLER (COMPUTER) RELAY
OUTPUT L.E.D. (LIGHT EMITTING DIODE) INDICATORS
There are a series of five (5) L.E.D. (light emitting diode) indicators (ORANGE LIGHTS) located at the backside
of the Phase 6 OPL microprocessor controller (computer). These are identified or labeled (from top to bottom in
the illustration below as: FAN-BLOWER, FOR-FORWARD, REV-REVERSE, AIR-AIR-JET, HT1-HEAT
OUTPUT. There are a series of seven [7] L.E.D. (light emitting diode) indicators [red lights] FUSE-MAIN
FUSE, LINT-LINT DOOR, MAIN-MAIN DOOR, DRUM-TUMBLER HI-LIMIT, SAIL-SAIL SWITCH,
BURN-BURNER HI LIMIT, FLAME-FLAME PROBE). The L.E.D. (light emitting diode) in the center of the
board (red light) indicates power supplied to the Phase 6 OPL microprocessor controller (computer). These
L.E.D.s (light emitting diode) indicate the inputs and outputs of the Phase 6 OPL microprocessor (computer) as
it monitors the safety circuits.