A SERVICE OF

logo

LXE Diagnostics 121
E-EQ-MX3RG-J-ARC MX3 Reference Guide
6. Press <E> key to return to the menu.
Process - Get Compensated Data:
1. Select 5 for Polled Mode. “Polled” is displayed for a few seconds and is then erased.
2. Select 2 or 4 (as desired) and the test criteria are displayed on the screen. For
example, upon selecting (2), “8-Bit”, “Compensated” and “Polled” are displayed on
the screen for a few seconds.
3. The next screen displays two arrows and three crosshairs diagonally from left to
right – x,y coordinates of either 0,0 or 640,240 are also displayed.
4. With a stylus, press on the tip of the arrows and in the center of the crosshairs one at
a time, starting from the bottom left arrow.
5. The x,y coordinates should be within these ranges:
Arrow Location x y
Left bottom arrow tip -5 to 5 -5 to 5
Left lower crosshair center 154 to 164 54 to 64
Middle crosshair center 314 to 324 114 to 124
Upper right crosshair center 474 to 484 174 to 184
Upper right arrow tip 634 to 644 234 to 244
6. Press <E> key to return to the menu.