E-EQ-MX3RG-J-ARC MX3 Reference Guide
Example – Enable COM2 for
Tethered Scanner
The process used to enable the MX3 COM2 port for use with a tethered scanner has three steps:
1. BIOS Setup
Select Advanced Menu / Select Other / Select COM2 Pin9:
Change the parameter value to 5V.
Select Exit Menu / Save and Exit
2. Terminal Emulation Configuration Utility (if used) e.g. ANSI Plus TE:
Select System Menu / RFFileModeCfg
Change the parameter value to Comm1 Out, Comm2 In
Select Exit with Save Option.
3. DOS
Add the following line to the AUTOEXEC.BAT file on the line above any existing
SETAPI_4 commands:
SETAPI_4 15 ba 56 31 01 x x
Note: If COM1 port is an integrated scanner, the integrated scanner is disabled by this
procedure.