Whirlpool 3395339 Clothes Dryer User Manual


 
Product Damage
Keep air openings free of dry-
cleaning fluid fumes. Fumes
create acids which, when drawn
through the dryer heating units,
can damage dryers and loads
being dried.
L
A clean-out cover should be located
on the main exhaust duct for
periodically cleaning the exhaust
system.
An exhaust hood should cap the
outside end of the main duct to
prevent exhausted air from returning
to the dryers. If an exhaust hood
cannot be used, the outside end of
the main duct should have a sweep
elbow directed downward. If the
main duct travels vertically through
the roof rather than through the wall,
install 180” sweep elbow on the end
of duct at least 2 feet above the
highest part of the building. The
opening wall or roof shall have a
diameter l/2 inch larger than the
exhaust duct diameter. The exhaust
duct should be centered in the
opening.
exhaust
hood or
Exhaust duct
connection
Electrical Shock Hazard
Disconnect both power supply
cords before making these
changes.
Failure to do so may result in
electrical shock or personal injury.
Determine which direction you need
to attach the exhaust ducts to the
dryers. Both dryers can be exhausted
straight out the back or from the right
or left side. The lower dryer can also
be exhausted through the bottom.
Next, determine the length of exhaust
duct you will need to connect the
dryers to exhaust hoods or the main
exhaust.
To connect exhaust duct
straight out the back-
l-l
RI+
wall
2
ft.
min.
highest point of
180
sweep
main collector
Do Not install screening cap over end
of duct.
Attach exhaust duct to each dryer
duct. Then connect exhaust ducts to
exhaust hoods or main exhaust. Use
duct tape to seal all joints.
This dryer may be converted to be
exhausted out the right or left side or
through the bottom. To convert the
dryer, one of the following kits MUST
be used:
Exhaust Kit No. 279818 (White)
Exhaust Kit No. 279819 (Almond)
Follow the instructions in the Kit to
avoid operational and personal
hazard.
Page 6