Miele G 7824 Washer User Manual


 
Warning and Safety
instructions
,
These warning and safety
instructions are in addition to those
given at the beginning of this
booklet.
~
H
2
O
2
solution must only be used in
the special containers and adapters
provided by the Ecolab and Dr. Weigert
companies.
~
Important: observe the
manufacturer's safety instructions as
given on their safety data sheet.
~
Be especially careful when handling
H
2
O
2
solution. It is an irritant chemical.
Observe all current safety instructions
pertaining to its use.
Wear protective gloves and goggles.
~
Empty containers must be disposed
of in accordance with the
manufacturer's instructions.
~
H
2
O
2
solution must not be mixed
with other chemicals. This could cause
a serious chemical reaction, e. g. the
release of harmful vapours or gases.
~
Only use tenside cleaning agents
supplied by Ecolab or Dr. Weigert.
Connecting the H
2
O
2
solution
container
The connection hose for the H
2
O
2
solution container is identified by a
black label. The connection hose is
supplied without a safety cap as the
container for hydrogen peroxide will
vary depending on supplier.
^
Connect the supplier's safety cap to
the connection hose (black).
^
Then connect this to the H
2
O
2
solution container.
^ Then start the
DOS2-FILL
programme.
Unlike with other chemical agents the
H
2
O
2
solution container must be fully
emptied before it is exchanged for a
new one.
Do not replace the H
2
O
2
solution
container with a new one until the
FILL
DOS 2 CONTAINER
message is
displayed. After connecting the new
container you must run the
DOS2-FILL
programme.
If the
CHECK DISPENSING SYSTEM 2
message appears you should check
the container as well as the dispensing
system. The programme will stop
automatically.
Special processes - OXIVARIO and ORTHOVARIO
65