Maytag MDE/MDG21PNA Washer/Dryer User Manual


 
36 16022904 Rev. 0 ©2004 Maytag Appliances Company
Troubleshooting Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to unit before servicing, unless testing
requires power.
Stack Dryer Diagnostic Code
d12 or d14 Motor
Sensed Problem
d12 indicates
lower dryer motor
sense. d14
indicates upper
dryer motor sense
Clear diagnostic
code by pushing a
Delicates keypad
for at least 1
second while code
is displayed.
Does
diagnostic code
remain?
False indication
control board
Replace control
board
No
Yes
d9
Voltage Problem
Less Than 90 VAC
Try to clear the
diagnostic code by
pressing the
Delicates keypad
for more than 1
second while the
code is displayed.
Exit service mode , and pause for
10 seconds, enter service mode.
Did the
diagnostic code
cancel?
Low voltage was
sensed on the
power line, but is
now ok.
Yes
No
Install reader or use PDA to change mode out of
Gen 2 debit mode
Check wiring
between debit
card reader
and control
board
Is card reader
installed?
Power down and
up machine to
reset card reader
Replace card
reader or
control board.
No
d16
PR Models Only
Check installation
to insure proper
power going to this
dryer. If d9
persist, check the
wiring or replace
the transformer
Are other machines
at this location giving a d9
diagnostic code?
Check installation
to insure proper
power going to all
of the dryers
If problem persists replace
the control board.
YesNo