Cissell CSBBYMV Clothes Dryer User Manual


 
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Operation
AJ0976
14
8. Press the head release button. Heads should open
and buck should return to the dressing station.
9. Simultaneously press and release both buck in
buttons. As buck travels into cabinet, press red
safety bar which is near the operator. Buck travel
should stop, press heads should remain open and
air should exhaust from the system. Pressure
gauge should read 0 psi.
10. Reset air to press. Simultaneously press and
release both buck in buttons. Allow buck to travel
into cabinet and heads to close. Press other red
safety bar. Press heads should open, buck should
remain stationary and air should exhaust from the
system. Pressure gauge should read 0
psi.
11. Reset air to press. Simultaneously press and
release both buck in buttons. Allow buck to travel
into cabinet and heads to close. Press emergency
stop button. Press heads should open, buck
should remain stationary and air should exhaust
from the system. Pressure gauge should read
0
psi.
Electrical Check-Out
Black and red electrical control buttons start and stop
all electrical functions.
1. Reset air to press per step 1 in Buck Indexing
Mechanical Check-Out. Turn electrical on to
press at fused disconnect switch or circuit
breaker.
2. Make sure Emergency Stop button is up if
applicable.
3. Press black start button.
NOTE: Start button will not start blower unless air
is reset to press.
4. Check blower for proper rotation. Check airflow
direction at press muffler. Air should be
exhausting from muffler. If air is sucked in
toward muffler, change any two wires in the
electrical connection box.
5. Check isolation damper between sleeve heat
exchanger and blower. Air cylinder should extend
to open damper.
6. Step on left foot pedal. Vacuum should turn on to
buck. Press vacuum release button. Vacuum
should turn off to buck.
7. Set cycle timer selector switch to on position and
set pressing cycle timer for approximately
35
seconds. Turn steam timer selector switch to
off position. Send buck into pressing position.
Heads should close and remain closed for
approximately 35 seconds.
8. When press heads open, the buck should
automatically return to the dressing position.
9. Turn steam timer selector switch to the on
position. Set steam timer for 5 seconds. Send
buck into pressing position. Blower air should
blow through arm holes after a 5 second delay
and remain on until cycle timer times out.
10. After all checks (steps 1 through 9) are
completed, proceed with Steam Injection and
Temperature Check-Out.
CAB240N
Figure 6
1/8 in.
(3 mm)
1/8 in.
(3 mm)
1/8 in.
(3 mm)
To avoid possible serious injury, NEVER
use press unless BOTH safety bars and
BUCK IN BUTTONS are working properly.
W369
WARNING