Operation
AJ0976
8
Shipping Information
NOTE: Applicable codes, ordinances, specifications
and/or other governing data related to installation
must be complied with. The materials listed in
Table 1 may or may not conform to these
requirements.
Materials Required
Table 1
U.S.A. Metric
Length
111 in. 282 cm
Width
42 in. 107 cm
Height
82 in. 208 cm
Weight
2470 lbs. 1120 kg
Quantity Description Source
1 Lockout type fused disconnect switch suitable for the electric service connected to
the press (refer to wiring schematic in control box) (not required if circuit breaker is
used)
Local
As required Wire of suitable size, type and length to connect the electric service to the press
(refer to wiring schematic in control box)
Local
As required Flexible conduit and connections to encase the wires and make connections
(refer to wiring schematic in control box)
Local
3 Steam trap and check valve, or combination steam trap/check valve sized steam
return lines and steam consumption
Local
3 Ball shut-off valves sized for steam supply, return lines and air supply Local
As required Pipe, couplings, unions, flanges, etc., to connect steam supply and return lines and
air supply line to press. Wall thickness of pipe and tubing must be in compliance
with recommendations by compressor and boiler manufacturers and local code.
Local
6 5/8 in. anchor bolts Local
As required Machinery grout (if machine sits 1/2 in. [12.7 mm] or greater off of floor) Local
As required Pipe, couplings, unions, flanges, etc., to route air bag blower exhaust away from the
press
Local