SAFETY DEVICES LOCATION FUNCTION
COMPUTER
DISPLAY MESSAGE
RESULT OF
TRIPPING
LOAD DOOR SWITCH
LEFT SIDE OF LOAD
DOOR
INSURES DRYER LOAD
DOOR ARE CLOSED
"DOOR OPEN" DRYER WILL NOT RUN
UNLOAD DOOR
SWITCH (TWO DOOR
UNIT ONLY)
RIGHT SIDE OF
UNLOAD DOOR
INSURES DRYER
UNLOAD DOORS ARE
CLOSED
"DOOR OPEN" DRYER WILL NOT RUN
TILTING SWITCHES
TOP LEFT SIDE OF
BASE MODULE
INSURES DRYER IS
LEVEL
"LEVEL FAULT" DRYER WILL NOT RUN
DRUM ROTATION
SENSOR
LEFT SIDE OF
TUMBLER SECTION
INSURES TUMBLER IS
ROTATING
"DRUM FAULT" STOPS HEAT ONLY
LINT CHAMBER AIR
PRESSURE SWITCH
CENTER OF HEAT
CONSOLE
INSURES PROPER AIR
FLOW THROUGH DRYER
"AIRFLOW
FAULT"
STOPS HEAT ONLY
BURNER FAN AIR
FLOW SWITCH (GAS
DRYERS ONLY)
CENTER OF HEAT
CONSOLE
INSURES PROPER
CAOMBUSTION AIR
FLOW INTO THE
BURNER BOX
"HEATER FAULT" STOPS HEAT ONLY
HI/LO GAS PRESSURE
SWITCH (GAS DRYERS
ONLY)
LOWER LEFT OF HEAT
CONSOLE SECTION
INSURES PROPER GAS
SUPPLY PRESSURE FOR
ADEQUATE IGNITION
"GAS SUPPLY
FAULT"
STOPS HEAT ONLY
HEAT RECLAIMER
DAMPER SWITCH
RIGHT SIDE OF HEAT
CONSOLE
INSURES THAT THE
HEAT RECLAIMER IS
EITHER OPENED OR
CLOSED
INPUT LED #13 OF
THE PLC IS OFF
NONE
HEAT CONSOLE DOOR
ACCESS DOOR
SWITCH
INSIDE HEAT
CONSOLE
INSURES THAT ACCESS
DOORS ARE CLOSED
"DOOR OPEN" DRYER WILL NOT RUN
EXHAUST AIR TEMP
CONTROL SENSOR
INSIDE BURNER
SECTION DUCT
MONITORS TUMBLER
EXHAUST AIR TEMP
"EXHAUST DSFL" STOPS HEAT ONLY
EXHAUST AIR HI
TEMP CONTROL
SENSOR
INSIDE EXHAUST DUCT
MONITORS TUMBLER
EXHAUST AND AIR TEMP
"HI-TEMP FAULT" STOPS HEAT ONLY
INTAKE AIR TEMP
CONTROL SENSOR
(OPTIONAL)
TOP RIGHT OF
TUMBLER SECTION
MONITORS TUMBLER
AIR INTAKE TEMP
"INTAKE DSFL" STOPS HEAT ONLY
INTAKE AIR TEMP
CONTROL SENSOR
TOP RIGHT OF
TUMBLER SECTION
MONITORS TUMBLER
AIR INTAKE TEMP
"HI-TEMP FAULT" STOPS HEAT ONLY
BURNER HI-LIMIT
SAFETY SENSOR
TOP OF BURNER
SECTION
MONITORS AIR TEMP
ABOVE THE BURNER
BOX
"HI-TEMP FAULT" STOPS HEAT ONLY
SPRINKLER CONTROL
SAFETY SENSOR
TOP RIGHT OF
TUMBLER SECTION
OPEN SPRINKLER
SYSTEM WATER VALVE
ON HI-TEMP CONDITION
ORANGE SPRINKLER
PILOT LIGHT COMES
ON. ALARM HORN
SOUNDS
OPENS THE SPRINKLER
WATER VALVE AND
POWER DOWN THE
WHOLE DRYER
LINT DRAWER
SWITCHES
ABOVE LINT DRAWER
HANDLES
DISABLES MACHINE
WHEN DRAWERS ARE
OPEN OR IF DRAWERS
HAVE NOT BEEN
CLEANED IN LAST FIVE
LOADS.
LINT DRAWER DRYER WILL NOT RUN