17
e. Tumbler Junction Box Disconnect
Remove the four (4) bolts that hold on the lower left side panel, then remove the panel. The safety panel
is next to be removed. This is done by removing the six (6) bolts on the bottom of the safety panel where
the tumbler section and the base meet. Reach into the feed through hole in the base of the tumbler section,
there will be two (2) cables there. Pull both cables through the hole into the tumbler section. The cable
Leave that cable in the tumbler section (it will be covered in Section f below [Left Drum Motor]). Check
keying between the plug and tumbler junction box. Insert plug into connector on the junction box and
engage locking clasps. Leave the lower left side panel and the safety panel off the machine until left drum
motor is reconnected (refer to Section f below [Left Drum Motor]).
f. Left Drum Motor
There are two (2) different ways that the left drum motor is connected with or without the motor
disconnected junction box. The junction box is used when the connections to the left motor are made on
the back side of the motor, nearest to the tumbler basket. When connecting the motor, bring the left drum
motor cable (refer to Section e above [Tumbler Junction Box Disconnect]) and mechanically connect it
to the junction box on the motor or the external junction box with the lock nut. There will be four (4) wires
in the cable, match them with the PVC electrical tape. There should be one (1) green wire remaining,
which is used for the ground connection. Replace the screws that go on the cover of the junction box.
Bolt the safety panel back in place using the six (6) bolts removed in Section e above (Tumbler Junction
Box Disconnect), then bolt the lower left side panel back in to place using the four (4) bolts also removed
in Section e above (Tumbler Junction Box Disconnect).